On this page you find facts and figures about the 5GDHC network in Maikammer (Eulbusch III). The network has a length of 0.65 km. In total, 37 buildings are supplied by the heat network. The 5GDHC network is operated by Pfalzwerke AG .

Facts and figures about the cold heat network in Maikammer (Eulbusch III)

Geothermal probes, which are one of the most common heat sources for 5GDHC networks, serve as a heat source in this district. Uninsulated plastic pipes are used for the heating network. The network does not only supply the buildings with heat to operate the decentralized heat pumps, but also with cooling energy, e.g. for room air conditioning. If heating and cooling demands occur simultaneously, these can be balanced within the 5GDHC network (see also demand balancing in 5GDHC networks). The district comprises new construction areas only. Every building of the district is free to decide whether to connect to the heating network or not; there is no obligation to connect. Detailed data of the 5GDHC network in Maikammer (Eulbusch III) is listed in Table 1.

Table 1: Facts and figures about the anergy network in Maikammer (Eulbusch III)
DistrictEulbusch III
CountryGermany
City / locationMaikammer
Year of commissioning2022
OperatorPfalzwerke AG
Network temperatures3-10 °C
Supplied buildings37
Network length0.65 km
Share of new building area100 %
Pipe typePlastic pipe (uninsulated)
Heat sourcesGeothermal probes Shallow geothermal energy
Cooling supply through thermal networkYes
Obligation to connect to networkNo
Owner of decentral heat pumpsHome/building owner
Price model for heat supplyBase price (€/year)
Buildings receiving compensation for heat feed-inNo